Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17

27

5

Installation

5.2

Electrical installation

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2

Electrical installation

5.2.1

Wiring according to EMC guidelines

In typical systems, standard shielding is sufficient for Ethernet cables.
However, in environments with a very high level of interference, EMC resistance can be improved

by additionally earthing the cable shield on both sides.
For this observe the following notes:

1. Remove the plastic sheath of the cable at a length of 2 cm.
2. Fasten the cable shield to the shield support of the standard device.

5.2.2

Network topology

It is typical of EtherNet/IP to have a rather free topology the limiting factor of which is large

message latencies due to e.g. switches connected in series.

Internal switch latency

( 21)

The combination of a line and a stub is useful for system wiring.
EtherNet/IP supports the following topologies:

• Line

[5-4]

Line topology (S = scanner, A = adapter)

• Switch / star

[5-5]

Switch / star topology (SW = switch, A = adapter)

Documentation for the standard device, host, system/machine
Observe the notes and wiring instructions contained in this documentation.

E94AYCEO008

A

A

S

A

A

E94AYCEO005

SW

A

A

A