C13881, C13881 | overall ethernet timeout time, C13885 – Lenze E84AYCEO User Manual

Page 120: C13885 | clear i/o data, C13899, C13899 | hostname, C13900, C13900 | firmware product type, C13901, C13901 | firmware compilation date

Advertising
background image

13

Parameter reference

13.1

Parameters of the communication module

120

Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13881

C13885

C13899

C13900

C13901

Parameter | Name:

C13881 | Overall Ethernet Timeout Time

Data type: UNSIGNED_16

Index: 10694 = 0x29C6

Setting of the overall monitoring time (see

Fault with regard to EtherNet/IP communication ( 88)

)

A change in the monitoring response becomes immediately effective.
Setting range

(min. value | unit | max. value)

Lenze setting

500

ms

65535 10000 ms

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13885 | Clear I/O Data

Data type: UNSIGNED_8

Index: 10690 = 0x29C2

Setting which I/O data are to be processed by the adapter to maintain internal communication if ...

• the network status of the controlling I/O connection is "Not connected" (see

C13862

) or

• an idle event has occurred.

Changes in the setting becomes effective immediately.

(See

Fault with regard to EtherNet/IP communication ( 88)

.)

Selection list

(Lenze setting printed in bold)

0 Use of last Scanner Output Data
1 Clear Scanner Output Data

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13899 | Hostname

Data type: VISIBLE_STRING

Index: 10676 = 0x29B4

Each subcode contains a string with a length of 32 bytes indicating the designation of the EtherNet/IP node.

(Instance attribute 6 (Host Name) in the

TCP/IP Interface Object (245 / 0xF5) ( 141)

)

Subcodes

Lenze setting

Info

C13899/1

Host name

C13899/2

Host name

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13900 | Firmware Product Type

Data type: VISIBLE_STRING

Index: 10675 = 0x29B3

The code contains a string with a length of 8 bytes. The identification code "E84AYCEO" is output.

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13901 | Firmware Compilation Date

Data type: VISIBLE_STRING

Index: 10674 = 0x29B2

The code contains a string with a length of 20 bytes. The software creation date ("MMM DD YYYY") and time

("hh:mm:ss") are displayed (e.g. "Mar 21 2005 12:31:21").

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Advertising