Write "DriveMode" attribute

In order to be able to use the torque control for the Assembly-Objektinstanzen 22 (0x16), 23 (0x17),

72 (0x48), 73 (0x49), the "DriveMode" attribute has to be written by means of explicit message

transfer.
In order to write the "DriveMode" attribute by means of explicit message transmission, the

following settings are required:

Settings

Value / description

Message Type

"CIP Generic"

Service Type

"Set Attribute Single" (service code "0x10")

Class

"2A" (AC Drive Object)

Instance

"1"

Attribute

"6" ("DriveMode" attribute )

Source Element

"Drive_Mode" (variable in the PLC program used as data source for writing.)

Source Length

"1 byte" (The variable data type is SINT.)