Rated data, Operation with rated power (normal operation), Technical data – Lenze E82EV 8200 vector 0.25kW-2.2kW User Manual

Page 103

Advertising
background image

Technical data

Rated data

Operation with rated power (normal operation)

3

l

103

EDK82EV222 DE/EN/FR 13.0

Rated data

Operation with rated power (normal operation)

For data for operation at rated mains voltage and switching frequency 8 kHz, sin. data and restrictions
for other switching frequencys see system manual.

Type

Power

Rated mains voltage

Mains current [A]

Output current [A]

Earth

[kW]

without

with

I

rated

I

max

(60 s)

1)

[kg]

P

rated

Mains choke

E82EV251K2C

3)

0.25

1/N/PE AC 230/240 V:

180 V −0 % ... 264 V +0 %
45 Hz −0 % ... 65 Hz +0 %

DC 325 V:

260 V −0 % ... 370 V +0 %

3.4

3.0

1.7

2.5

0.8

(E82CV... 0.6)

E82EV371K2C

3)

0.37

5.0

4.2

2.4

3.6

E82EV551K2C

0.55

6.0

5.6

3.0

4.5

1.2

(E82CV... 0.9)

E82EV751K2C

0.75

9.0

7.5

4.0

6.0

E82EV152K2C

1.5

15.0

12.5

7.0

10.5

1.6

(E82CV... 1.1)

E82EV222K2C

2)

2.2

18.0

9.5

(E82CV... 8.5)

14.2

E82EV551K2C

0.55

3/PE AC 230/240 V:

180 V −0 % ... 264 V +0 %
45 Hz −0 % ... 65 Hz +0 %

DC 325 V:

260 V −0 % ... 370 V +0 %

3.9

2.7

3.0

4.5

1.2

(E82CV... 0.9)

E82EV751K2C

0.75

5.2

3.6

4.0

6.0

E82EV152K2C

1.5

9.1

6.3

7.0

10.5

1.6

(E82CV... 1.1)

E82EV222K2C

2)

2.2

9.0

9.5

(E82CV... 8.5)

14.2

E82EV551K4C

0.55

3/PE AC 400 V:

320 V −0 % ... 440 V +0 %
45 Hz −0 % ... 65 Hz +0 %

DC 565 V:

450 V −0 % ... 620 V +0 %

2.5

2.0

1.8

2.7

1.2

(E82CV... 0.9)

E82EV751K4C

0.75

3.3

2.3

2.4

3.6

E82EV152K4C

1.5

5.5

3.9

3.9

5.9

1.6

(E82CV... 1.1)

E82EV222K4C

2.2

7.3

5.1

5.6

8.4

E82EV551K4C

0.55

3/PE AC 500 V:

400 V −0 % ... 550 V +0 %
45 Hz −0 % ... 65 Hz +0 %

DC 710 V:

565 V −0 % ... 775 V +0 %

2.0

1.4

1.4

2.7

1.2

(E82CV... 0.9)

E82EV751K4C

0.75

2.6

1.8

1.9

3.6

E82EV152K4C

1.5

4.4

3.1

3.1

5.9

1.6

(E82CV... 1.1)

E82EV222K4C

2.2

5.8

4.1

4.5

8.4

1)

Currents for periodic load change: 1 min overcurrent time with I

max

and 2 min base load time with 75 % I

r

2)

Operation only permitted with mains choke (

^

120)

3)

DC supply not possible

Operation with increased rated power

,

System Manual

Advertising