Electrical installation – Lenze E82EV 8200 vector 0.25kW-2.2kW User Manual

Page 123

Advertising
background image

Electrical installation

Mains connection

Fuses and cable cross−sections according to EN 60204−1

5

l

123

EDK82EV222 DE/EN/FR 13.0

ELCB

1)

Cable cross−section

Rated fuse current

8200 vector

ELCB

1)

Laying system L1, L2, L3, N, PE

Circuit−breaker

Fuse

8200 vector

ELCB

1)

C

B2

Circuit−breaker

Fuse

8200 vector

[mA]

[mm

2

]

[mm

2

]

[A]

[A]

Type

E82xV251K2C

10

C10

1.5

³ 30

E82xV371K2C

10

C10

1.5

E82xV551K2C

10

B10

1.5

E82xV751K2C

10

B10

1.5

E82xV152K2C

16

B16

2 x 1.5

E82xV222K2C

16

B16

2 x 1.5

Mains 3/PE AC 230/240 V − operation without mains choke/mains filter

E82xV551K2C

6

B6

1

³ 30

E82xV751K2C

6

B6

1

E82xV152K2C

16

B16

2 x 1.5

E82xV222K2C

20

B20

2 x 1.5

Mains 3/PE AC 230/240 V − operation with mains choke/mains filter

E82xV551K2C

6

B6

1

³ 30

E82xV751K2C

6

B6

1

E82xV152K2C

10

B10

1.5

E82xV222K2C

16

B16

2 x 1.5

Mains 3/PE AC 400/500 V − operation without mains choke/mains filter

E82xV551K4C

6

B6

1

³ 300

2)

³ 30

3)

E82xV751K4C

6

B6

1

E82xV152K4C

10

B10

1.5

E82xV222K4C

10

B10

1.5

Mains 3/PE AC 400/500 V − operation with mains choke/mains filter

E82xV551K4C

6

B6

1

³ 300

2)

³ 30

3)

E82xV751K4C

6

B6

1

E82xV152K4C

10

B10

1.5

E82xV222K4C

10

B10

1.5

1)

Earth−leakage circuit breaker

2)

Is used with E82EVxxxKxC0xx (with integrated EMC filter)

3)

Is used with E82EVxxxKxC2xx (without integrated EMC filter)

4)

Pin−end connector required

Advertising