Troubleshooting and fault elimination – Lenze E82EV 8200 vector 0.25kW-2.2kW User Manual

Page 162

Advertising
background image

Troubleshooting and fault elimination

Fault elimination
Fault messages

8

l

162

EDK82EV222 DE/EN/FR 13.0

Remedy

Cause

Fault

PC

1)

Keypad

Pr

a

75

Faulty parameter
transfer via keypad

All parameter sets are defective

Before enabling the controller, repeat
the data transfer or load the Lenze
setting

Pr1

a

72

Faulty PAR1 transfer
via keypad

Parameter set 1 is defective

Pr2

a

73

Faulty PAR2 transfer
via keypad

Parameter set 2 is defective

Pr3

a

77

Faulty PAR3 transfer
via keypad

Parameter set 3 is defective

Pr4

a

78

Faulty PAR4 transfer
via keypad

Parameter set 4 is defective

Pr5

a

79

Internal fault

EEPROM is defective

Contact Lenze

Pt5

a

81

Time error during
parameter set
transfer

Data flow from keypad or PC
interrupted, e.g. keypad has been
removed during data
transmission

Before enabling the controller, repeat
the data transfer or load the Lenze
setting.

rSt

a

76

Error during
Auto−TRIP reset

More than 8 error messages
within 10 minutes

Dependent on the error message

sd5

a

85

Wire breakage,
analog input 1

Current on analog input < 4 mA
for setpoint range 4 ... 20 mA

Close the circuit at the analog input

sd7

a

87

Wire breakage,
analog input 2

1)

LECOM error number, display in Global Drive Control (GDC) parameter setting program