Troubleshooting and fault elimination – Lenze E82EV 8200 vector 0.25kW-2.2kW User Manual

Page 159

Advertising
background image

Troubleshooting and fault elimination

Fault elimination

Fault messages

8

l

159

EDK82EV222 DE/EN/FR 13.0

Remedy

Cause

Fault

PC

1)

Keypad

ce6

a

67

System bus (CAN)
function module on
FIF has the
"Warning" or
"BUS−OFF" status
(configurable in
C0126)

CAN controller reports "Warning"
or "BUS−OFF" status

l

Check bus termination

l

Check shield connection of the
cables

l

Check PE connection

l

Check bus load, reduce the baud
rate, if necessary

ce7

a

68

Communication
error during remote
parameterisation
via system bus
(C0370)
(configurable in
C0126)

Node does not respond or is not
available

l

Check bus termination

l

Check shield connection of the
cables

l

Check PE connection

l

Check bus load, reduce the baud
rate, if necessary

For operation with application
I/O:
Parameter set change−over has
been parameterised incorrectly

The "parameter set change−over"
signal (C0410/13, C0410/14) must be
connected to the same source in all
paramerter sets

EEr

a

91

External fault
(TRIP−SET)

A digital signal assigned to the
TRIP−Set function is activated

Check external encoder

ErP0
...
ErP19

a

Communication
abort between
keypad and
standard device

Various

Contact Lenze

FAn1

a

95

Fan failure
(only 8200 motec
3 ... 7.5 kW)
TRIP or warning
configurable in
C0608

Fan is defective

Replace fan

FAn1

Fan is not connected

Connect fan
Check wiring

H05

a

105

Internal fault

Contact Lenze

id1

a

140

Faulty parameter
identification

Motor is not connected

Connect motor

LP1

a

32

Motor phase error
(display when
C0597 = 1)

l

Failure of one/several motor
phases

l

Motor current is too low

l

Check motor supply cables

l

Check V

min

boost,

l

Connect motor with a
corresponding power or adapt
motor with C0599

LP1

182

Motor phase error
(Display when
C0597 = 2)