Mechanical installation

Mounting with thermal separation (push−through technique)

4

l

107

EDK82EV222 DE/EN/FR 13.0

Cutout in the control cabinet

Dimensions [mm]

8200 vector

a

1

b

1

Frame

E82DV251K2C

61

101

E82ZJ007V

E82DV371K2C

E82DV551KxC

161

E82ZJ003

E82DV751KxC

Mounting

3.

3.

2.

1.

1.

4.

5.

E82DV_001

1.

Slide on frame.

2.

Insert seal.

3.

Slide earthing clamps on the frame with the correct sides:
– The contact springs have to point towards the rear panel of the control cabinet.
– The cutouts of the seal specify the positions.

4.

Insert 8200 vector into cutout.

5.

Tighten by means of 8 screws M4x10.
– Tightening torque: 1.7 Nm (15 lb−in)