Troubleshooting and fault elimination – Lenze E82EV 8200 vector 0.25kW-2.2kW User Manual

Page 157

Advertising
background image

Troubleshooting and fault elimination

Fault elimination

Drive errors

8

l

157

EDK82EV222 DE/EN/FR 13.0

Remedy

Cause

Maloperation

C0084, C0087, C0088, C0089, C0090, C0091
and/or C0092 not adjusted to the motor data

Adjust codes manually or identify
motor parameters (C0148);
optimise vector control

Motor rotates, setpoints are 0"

A setpoint has been specified by the use of
the function

j of the keypad

Set setpoint to "0" with C0140 = 0

Motor parameter identification
stops with error LP1

Motor is too small in relation to the rated
power of the drive

DC injection brake (DCB) active via terminal

Unacceptable drive behaviour
with vector control

Various

Optimising the vector control

Torque dip in the field
weakening range
Stalling of the motor when
operating in the field weakening
range

Various

Contact Lenze