Scope of supply, Interfaces and displays – Lenze E82EV 8200 vector 0.25kW-2.2kW User Manual

Page 84

Advertising
background image

l

84

EDK82EV222 DE/EN/FR 13.0

Scope of supply

Position

Description

0

8200 vector frequency inverter

1

Label (required for mounting in accordance with UL)

^

104

2

Support for standard fixing

^

104

3

EMC shield sheet with shield clips for the motor cable and for the motor temperature
monitoring feed cable

^

119

4

2−pole terminal strip for motor PE and motor shield at X2.1

^

119

5

EMC shield sheet with fixing screws and shield clamp for shielded control cables

^

119

6

Plug connector 2*13 pole for function modules on FIF interface

^

130

X1.1

Terminal strip for mains connection, DC supply (3 − 7 pole, according to device type)

^

120

^

121

X1.2

Terminal strip for relay output

^

127

X2.1

Terminal strip for motor connection, connection of brake resistor (optional)

^

126

X2.2

Terminal strip for PTC connection or thermal contact (NC contact) of the motor

Mounting instructions

Interfaces and displays

Position

Description

Function



2 light−emitting diodes
(red, green)

Status display

^

154

‚

AIF interface
(automation interface)

Slot for communication modules

^

132

E82ZBC keypad, XT EMZ9371BC keypad

Fieldbus communication module type EMF21xx...,
e.g. PROFIBUS−DP EMF2133IB

ƒ

FIF interface
(function interface)

With cover for operation without function modules

Or slot for function modules

^

130

Standard I/O PT E82ZAFSC010

Application I/O PT E82ZAFAC010

Fieldbus function modules type E82ZAFxC...,
e.g. PROFIBUS−DP PT E82ZAFPC010