Caution, Header operation - d series – MacDon M150 SP User Manual

Page 100

Advertising
background image

HEADER OPERATION - D SERIES

Form 169017 / 169087 / 169095

98

Revision C


Example:

Windrower is operating at 8 mph with Header
Index “on” and set at 1.5. Display shows;

9.5 1.5 DRAP INDX

where

9.5 (8+1.5) is the draper speed in mph,

and

1.5 is the header index setting.

Windrower speed drops to 7.5 mph at same
Header Index setting. Display shows;

9.0 1.5 DRAP INDX

where

9.0 (7.5+1.5) is the draper speed in mph,

and

1.5 is the header index setting.

Windrower is operating at 8 mph with Header
Index “on” and set at 0.9. Display shows;

8.9 0.9 DRAP INDX

where

8.9 (8+0.9) is the draper speed in mph,

and

0.9 is the header index setting.

6.5.7.2

Draper Speed Independent of Ground
Speed

Set the speed of the draper independently of
ground speed as follows:

NOTE

This procedure can also be used to change
the draper speed “on the go”.

CAUTION

Check to be sure all bystanders have cleared
the area.

##.# = MPH or KPH

HEADER ENGAGED

ON CDM PRESS
FAST OR SLOW

DISPLAY SHOWS

##.# DRAPER SPEED

DONE

SPEED

O.K.?

NO

YES

PRESS

DISPLAY SELECTOR

FOR

DRAPER SPEED

HEADER INDEX

SWITCH -

OFF