Danger – MacDon M150 SP User Manual

Page 179

Advertising
background image

MAINTENANCE AND SERVICING

Form 169017 / 169087 / 169095

177

Revision C

7.10.2 COOLING BOX MAINTENANCE

The radiator and oil cooler should be cleaned daily
with compressed air, and more frequent cleaning
may be necessary in severe conditions.

The charge air cooler and air conditioning
condenser may also be cleaned at the same time.

To clean these components, refer to illustrations
below, and proceed as follows:

DANGER

Stop engine and remove key from ignition
before leaving Operator’s seat for any reason.
A child or even a pet could engage an idling
machine.

a. Stop engine, and remove key.

b. Raise engine compartment hood fully.

c. Push latch (A), and open screen assembly access

door (B). Secure with rod (C) stored inside the
screen door.

d. Rotate retainer (D), pull open condenser (E), and

secure with support rod at (F).

e. Lift lever (G) and lower guard (H). The guard

prevents the platform from inadvertently
contacting the oil cooler after it has been pulled
out of the cooling box.

f.

Pull open access door (J).

g. Slide out the oil cooler assembly (K) with handle.

If movement is restricted by hose (L), lift up on
hose so that it moves away from frame.

(continued next page)

L

K

D

E

F

K

H

J

G

A

B

C

Advertising
This manual is related to the following products: