Caution – MacDon M150 SP User Manual

Page 182

Advertising
background image

MAINTENANCE AND SERVICING

Form 169017 / 169087 / 169095

180

Revision C

7.11.1.3 Charging

CAUTION

Ventilate the area where batteries are

being charged.

Do not charge a frozen battery. Warm to

60

°F (16°C) before charging.

Do not connect or disconnect live circuits.

To prevent sparks, turn off charger and
connect positive cable first. If charging
battery in windrower, disconnect positive
battery cable before connecting charger
cable, then connect ground cable last,
away from battery.

Stop or cut back charging rate if battery

feels hot, or is venting electrolyte. Battery
temperature must not exceed 125

°F (52°C).

Follow all instructions and precautions

furnished by the battery charger
manufacturer. Charge at recommended
rates and times.

7.11.1.4 Boosting

A twelve volt battery can be connected in parallel
(+ to +) with the windrower battery. Use heavy
duty battery cables.

CAUTION

Gas given off by batteries is explosive.

Keep sparks and flames away from
batteries.

Make last connection and first

disconnection at a point furthest away
from the batteries.

Wear protective eye-wear when using a

booster battery.

Be sure everyone is clear of machine when

starting engine. Start engine from
Operator’s station only.


a. Move platform on right cab-forward side of

machine to open position to allow access to the
battery.

b. Remove red rubber cover (A) from windrower

battery positive terminal.

(continued next page)

A

Advertising
This manual is related to the following products: