MAINTENANCE AND SERVICING

Form 169017 / 169087 / 169095

183

Revision C

7.11.1.7 Preventing

Electrical System Damage

a. Carefully observe polarity when attaching booster

battery.

b. Do not short across battery or alternator terminals,

or allow battery positive (+) cable or alternator wire
to become grounded.

c. Be sure alternator connections are correct before

cables are connected to battery. Refer to
illustration below.

d. When welding on any part of the machine,

disconnect battery cables and alternator wire.
See also Section 7.1.1 Welding Precautions.

e. Always disconnect battery ground cable when

working with the alternator or regulator.

f.

Never attempt to polarize alternator or regulator.

g. If wires are disconnected from the alternator, use

the illustration below to ensure proper
reconnection.

h. Never ground the alternator field terminal or field

circuit.

i. Never connect or disconnect alternator or

regulator wires with battery connected or
alternator operating.

j.

Always disconnect cables from the battery when
using a charger to charge battery in windrower.

k. Ensure all cables are securely connected before

operating engine.

GROUND STUD
- BLACK CABLE

FIELD TERMINAL
- RED CABLE

Advertising