MacDon M150 SP User Manual

Page 234

Advertising
background image

M150 AND M200 ENGINE ERROR CODES

Form # 169017 / 169087 / 169095

232

Revision C

J1939 SPN

Description

J1939

SPN

J1939

FMI

Lamp
Color

Cummins

Engine

Code

CAT

Engine

Code

Cummins / Caterpillar Description

4 Amber 2374

Exhaust Gas Pressure Sensor Circuit - Voltage Below Normal, or
Shorted to Low Source

Fuel Pump

Pressurizing

Assembly #1

1347

3

Amber

272

High Fuel Pressure Solenoid Valve Circuit - Voltage Above Normal,

or Shorted to High Source

4

Amber

271

High Fuel Pressure Solenoid Valve Circuit - Voltage Below Normal,

or Shorted to Low Source

5 162

1779

Output current low

6 162

1779

Output current high

7

Amber

281

1779

High Fuel Pressure Solenoid Valve #1 - Mechanical System Not

Responding Properly or Out of Adjustment

Engine Oil

Change

Interval

1378

31

Maint

649

Change Lubricating Oil and Filter - Condition Exists

Auxiliary

Pressure

1388

3

Amber

297

Auxiliary Pressure Sensor Input # 2 Circuit - Voltage Above

Normal, or Shorted to High Source

4

Amber

298

Auxiliary Pressure Sensor Input # 2 Circuit - Voltage Below Normal,

or Shorted to Low Source

14

Red

296

Auxiliary Pressure Sensor Input 1 - Special Instructions

J1939 Error

1484

31

None

211

Additional Auxiliary Diagnostic Codes logged - Condition Exists

Control
Module

Identification

Input State

1563

2

Amber

1256

Control Module Identification Input State Error - Data Erratic,

Intermittent, or Incorrect

Accelerator

Pedal Position

2623

3

Amber

1239

Accelerator Pedal or Lever Position Sensor 2 Circuit - Voltage

Above Normal, or Shorted to High Source

4

Amber

1241

Accelerator Pedal or Lever Position Sensor 2 Circuit - Voltage

Below Normal, or Shorted to Low Source

System

Diagnostic

Code #1

2629

15

None

2347

Turbocharger Compressor Outlet Temperature (Calculated) - Data

Valid but Above Normal Operational Range - Least Severe Level

System

Diagnostic

Code #1

2789

15

None

2346

Turbocharger Turbine Inlet Temperature (Calculated) - Data Valid

but Above Normal Operational Range - Least Severe Level

Coolant

Pressure

2981

3

Amber

2115

Coolant Pressure 2 Circuit - Voltage Above Normal, or Shorted to

High Source

4

Amber

2116

Coolant Pressure 2 Circuit -Voltage Below Normal, or Shorted to

Low Source

18

Amber

2117

Coolant Pressure 2 - Data Valid but Below Normal Operational

Range - Moderately Severe Level

System

Diagnostic

Code # 1

3511

4

Amber

238

Sensor Supply Voltage #3 Circuit - Voltage Below Normal, or

Shorted to Low Source

3 Amber 239

Sensor Supply Voltage #3 Circuit - Voltage Above Normal, or

Shorted to High Source

Advertising
This manual is related to the following products: