OPERATOR’S STATION

Form 169017 / 169087 / 169095

38

Revision C

CAB - FORWARD / ENGINE RUNNING / HEADER ENGAGED

DRAPER HEADER / INDEX SWITCH ON

(Scroll Through Display with CDM Switch or GSL Switch)

DISPLAY (Lower or Upper Line)

DESCRIPTION

#####.# ENGINE HRS

Total Engine Operating Time.

#####.# HEADER HRS

Total Header Operating Time.

##.# ACRES/HOUR
##.# HECTARES/HOUR

(If Metric)

Actual Cutting Rate In Acres (Hectares)/Hour.

###.# SUB ACRES
###.# SUB HECTARES

(If Metric)

Area Cut Since Last Reset.
To Reset, Display SUB ACRES On Lower Line And Hold
Down Program Switch Until Display Resets
(5 - 7 Seconds).

###### TOTAL ACRES
###### TOTAL HECT

(If Metric)

Total Area Cut By Machine.

##.## ##.# REEL IND

.

##.## REEL SENSOR

(Sensor Disabled)

Reel Peripheral Speed Along With Ground Speed In MPH
Or KPH.

##.# ##.# DRAP INDX

Draper Speed Along With Ground Speed In MPH Or
KPH.

#### KNIFE SPEED
#### KNIFE SENSOR

(Sensor Disabled)

Knife Speed In Strokes Per Minute.

##.# HEADER HEIGHT
##.# HEIGHT SENSOR

(Sensor Disabled)

Distance Setting (00.0 - 10.0) Between Cutterbar and
Ground.

##.# HEADER ANGLE
##.# TILT SENSOR

(Sensor Disabled)

Angle Setting (00.0 - 10.0) Header Relative To Ground.

##.# L FLOAT R ##.#

Left And Right Float Setting (0.0 - 10.0).

LOAD|■■■■■_____| ####

(If Metric)

#####

Bar Graph Representing Hydraulic Operating Pressure.
Full Scale Is Pre-Programmed Overload Pressure
(M150: 2500 -4000 PSI; M200: 2500 - 4800 PSI).
If Sensor Disabled, LOAD Does Not Display. See Note.

##.# VOLTS

Engine Electrical System Operating Voltage.

SCROLL

SUB-MENU (Lower Line Only)

#### KNIFE SPEED

##.# HEADER HEIGHT

LOAD|■■■■■■■■■■■■|

####

##.## REEL IND

##.# DRAP INDX

Displays Sub-Menu After 2 - 3 Seconds.
Press SELECT to cancel.
Scroll Through Sub-Menu Display with CDM Switch

##.## REEL MIN RPM

(Lower Line)

Reel Speed Drops Below Programmed Set-Point.

MINIMUM

(Lower Line)

Reel Speed At Zero Ground Speed.

NOTE: The load sensor is factory installed on M200 (optional for M150) to monitor knife/conditioner circuit pressure. To monitor
reel circuit pressure, relocate sensor as per Instructional Manual #169031 which is available through your MacDon Dealer.