Troubleshooting – MacDon M150 SP User Manual

Page 216

Advertising
background image

TROUBLESHOOTING

* See your MacDon Dealer
** Refer to Windrower Technical Manual

Form 169017 / 169087 / 169095

214

Revision C

SYMPTOM PROBLEM

SOLUTION

SECTION

M150 M200

High Fuel

Consumption.

Improper type of fuel.

Use proper fuel.

7.3.1.1

Clogged or dirty air cleaner.

Service air cleaner.

7.8.5.1 7.9.4.1

Engine overloaded.

Reduce ground speed.

6.3.6.2

Improper valve clearance.

Reset valves.

*

Engine out of time.

Contact MacDon Dealer.

*

Low engine temperature.

Check thermostat.

**

Injection nozzles dirty.

Contact MacDon Dealer.

*

Engine Emits

Black Or Grey

Exhaust.

Improper type of fuel.

Consult your fuel supplier, and use proper
type fuel for conditions.

7.3.1

Engine overloaded.

Reduce ground speed.

6.3.6.2

Clogged or dirty air cleaner.

Service air cleaner.

7.8.5.1 7.9.4.1

Defective muffler.

Check muffler for possible damage which
might create back pressure.

7.8.9 7.9.9

Dirty or faulty injectors.

Contact MacDon Dealer.

*

Engine out of time.

Air in fuel system.

Engine Emits

White Exhaust.

Improper type of fuel.

Consult your fuel supplier, and use proper
type fuel for conditions.

7.3.1

Cool engine.

Warm engine up to normal operating
temperature.

6.3.5.2

Defective thermostat.

Remove and check thermostat.

**

Engine out of time.

Contact MacDon Dealer.

*

Starter Cranks

Slowly Or Will Not

Operate.

Low battery output.

Check battery charge.

7.11.11.1

Controls not in neutral.

Move GSL to neutral.

6.3.6

Move steering wheel to center position.

6.3.5.1

Disengage header.

5.17.1

Relay not functioning.

Check relay and wire connections.

7.11.13

Loose or corroded battery
connections.

Clean and tighten loose connections.

7.11

Key switch worn or terminals loose. Contact MacDon Dealer.

*

Crankcase oil too high viscosity.

Use recommended oil.

7.3.1.3

Main fuse defective/blown.

Replace main fuse.

7.11.13

Key power fuse blown.

Replace.

Switch at interlock not closed or
defective.

Adjust switch or replace.

*

Air Filters Require

Frequent

Cleaning.

Vacuator plugged.

Clean out vacuator.

7.8.5.1

7.9.4.1

Pre-cleaner rotor not turning freely. Repair/replace.

7.10.1