Operator’s station – MacDon M150 SP User Manual

Page 52

Advertising
background image

OPERATOR’S STATION

Form 169017 / 169087 / 169095

50

Revision C

5.18.6 SETTING GUIDELINES

5.18.6.1 Pressure

Settings

WINDROWER

MODEL

HEADER MODEL

APPLICATION/SYSTEM

SUGGESTED OVERLOAD

WARNING SETTING

psi (kPa)

WINDROWER

PRESSURE COMP

SETTING

psi (kPa)

M150

D60 and A40D

Reel / Draper Pressure

3000 (20684)

3200 (22063)

M150

D60 and A40D

Knife / Conditioner Pressure

4000 (27579)

4200 (28958)

M150

R80

Disc Pressure

4000 (27579)

4200 (28958)

M200

R80

Disc Pressure

4300 (29647)

4500 (31026)

M200

D60 and A40D

Reel / Draper Pressure

3000 (20684)

3200 (22063)

M200

D60 and A40D

Knife / Conditioner Pressure

4300 (29647)

4500 (31026)

5.18.6.2 R Series Rotary Header Disc Speeds

CROP

CONDITION

DISC RPM *

Alfalfa

Heavy

2100 - 2300

Light

1800 - 2000

Sudan, Sorghum,
Haygrazer,
Timothy

Tall and

Stemmy

2300 - 2500

Short Grass

Dense 2500

Thin

2000 - 2200


*Suggested Overload Setting - 1300 rpm.

5.18.6.3 Engine Error Codes

The CDM displays “Error Codes” when there is a
fault with one of the several sensors that monitor
and control engine operation, to assist the
operator or technician in locating a specific
problem with engine operation.

Refer to the Appendix for the “Error Codes”.

5.18.7 CDM AND WCM FAULT CODES

The CDM displays “Fault Codes” when there is a
fault with one of the several sensors that monitor
and control windrower operation, to assist the
operator or technician in locating a specific
problem with the windrower.

Refer to the Appendix for the “Fault Codes”.

Advertising
This manual is related to the following products: