Viewing and editing parameters, Viewing and editing parameters -4 – Rockwell Automation 22F PowerFlex 4M User Manual FRN 1.xx - 2.xx User Manual

Page 38

Advertising
background image

2-4

Start Up

PowerFlex 4M Adjustable Frequency Drive FRN 1.xx - 2.xx User Manual
Publication 22F-UM001D-EN-E

The last user-selected Display Group parameter is saved when power is removed and is displayed by
default when power is reapplied.

The following is an example of basic integral keypad and display functions. This example provides basic
navigation instructions and illustrates how to program the first Program Group parameter.

Speed
Potentiometer

Used to control speed of drive. Default is active.

Controlled by parameter

P108

[Speed Reference].

Start

Used to start the drive. Default is active.

Controlled by parameter

P106

[Start Source].

Reverse

Used to reverse direction of the drive. Default is active.

Controlled by parameters

P106

[Start Source] and

A434

[Reverse Disable].

Stop

Used to stop the drive or clear a fault. This key is always
active. Controlled by parameter

P107

[Stop Mode].

No. LED

LED State

Description

Viewing and Editing Parameters

Step

Key(s)

Example Displays

1. When power is applied, the last user-selected

Display Group parameter number is briefly
displayed with flashing characters. The display
then defaults to that parameter’s current value.
(Example shows the value of d001 [Output
Freq] with the drive stopped.)

2. Press Esc once to display the Display Group

parameter number shown on power-up. The
parameter number will flash.

3. Press Esc again to enter the group menu. The

group menu letter will flash.

4. Press the Up Arrow or Down Arrow to scroll

through the group menu (d, P, t, C and A).

Press Enter or Sel to enter a group. The
rightmost digit of the last viewed parameter in
that group will flash.

5. Press the Up Arrow or Down Arrow to scroll

through the parameters in the group.

or

or

or

VOLTS
AMPS
HERTZ

FAULT

PROGRAM

VOLTS
AMPS
HERTZ

FAULT

PROGRAM

VOLTS
AMPS
HERTZ

FAULT

PROGRAM

VOLTS
AMPS
HERTZ

FAULT

PROGRAM

VOLTS
AMPS
HERTZ

FAULT

PROGRAM