A424, A419, Advanced program group – Rockwell Automation 22F PowerFlex 4M User Manual FRN 1.xx - 2.xx User Manual
Page 62: Continued)
3-22
Programming and Parameters
PowerFlex 4M Adjustable Frequency Drive FRN 1.xx - 2.xx User Manual
Publication 22F-UM001D-EN-E
Advanced Program Group
(continued)
A419 [Skip Freq Band]
Related Parameter(s):
Determines the bandwidth around
[Skip Frequency]. A419 [Skip Freq Band] is applied above
and below the actual skip frequency. See the diagram below.
A setting of 0.0 disables this parameter.
Values
Default:
0.0 Hz
Min/Max:
0.0/30.0 Hz
Display:
0.1 Hz
Frequency
Time
Skip Frequency
Command
Frequency
Drive Output
Frequency
2x Skip
Frequency Band
A424 [DC Brake Time]
Related Parameter(s):
Sets the length of time that DC brake current is “injected” into the motor. Refer to parameter
Brake Level].
Values
Default
0.0 Secs
Min/Max:
0.0/99.9 Secs (A setting of 99.9 = Continuous)
Display:
0.1 Secs