3-6

Programming and Parameters

PowerFlex 4M Adjustable Frequency Drive FRN 1.xx - 2.xx User Manual
Publication 22F-UM001D-EN-E

Display Group

(continued)

d014 [Dig In Status]

Related Parameter(s):

t201

,

t202

Status of the control terminal block digital inputs.

Values

Default

Read Only

Min/Max:

0/1

Display:

1

1 = Input Present, 0 = Input Not Present

Digital In1 Sel (I/O Terminal 05)

Bit 0

Digital In2 Sel (I/O Terminal 06)

Bit 1

Reserved

Bit 2

Reserved

Bit 3

d015 [Comm Status]

Related Parameter(s):

C302

-

C306

Status of the communications ports.

Values

Default

Read Only

Min/Max:

0/1

Display:

1

1 = Condition True, 0 = Condition False

Receiving Data

Bit 0

Transmitting Data

Bit 1

RS485 (DSI) Based Option Connected

Bit 2

(Allen-Bradley devices only.)

Communication Error Occurred

Bit 3

d016 [Control SW Ver]

Main Control Board software version.

Values

Default

Read Only

Min/Max:

1.00/99.99

Display:

0.01

d017 [Drive Type]

Used by Rockwell Automation field service personnel.

Values

Default

Read Only

Min/Max:

1001/9999

Display:

1