Supplemental drive information a-5 – Rockwell Automation 22F PowerFlex 4M User Manual FRN 1.xx - 2.xx User Manual

Page 85

Advertising
background image

Supplemental Drive Information

A-5

PowerFlex 4M Adjustable Frequency Drive FRN 1.xx - 2.xx User Manual

Publication 22F-UM001D-EN-E

PowerFlex 4M Estimated Watts Loss (Rated Load, Speed & PWM)

Voltage

kW (HP)

Watts Loss

100–120V, 1-Phase

0.2 (0.25)
0.4 (0.5)
0.75 (1.0)
1.1 (1.5)

17
28
50
76

200–240V, 1-Phase

0.2 (0.25)
0.4 (0.5)
0.75 (1.0)
1.5 (2.0)
2.2 (3.0)

14
25
43
82
109

200–240V, 3-Phase

0.2 (0.25)
0.4 (0.5)
0.75 (1.0)
1.5 (2.0)
2.2 (3.0)
3.7 (5.0)
5.5 (7.5)
7.5 (10)

16
26
44
84
115
159
239
329

380–480V, 3-Phase

0.4 (0.5)
0.75 (1.0)
1.5 (2.0)
2.2 (3.0)
3.7 (5.0)
5.5 (7.5)
7.5 (10)
11 (15)

24
41
74
92
135
190
294
378