d012 [Control Source]

Related Parameter(s):

P106

,

P108

,

t201

,

t202

Displays the active source of the Start Command and Speed Command which are normally defined
by the settings of

P106

[Start Source] and

P108

[Speed Reference] but may be overridden by digital

inputs. Refer to the flowcharts on pages

1-19

and

1-20

for details.

Values

Default

Read Only

Min/Max:

0/9

Display:

1

Start Command

Digit 0

0 = Keypad
1 = 3-Wire
2 = 2-Wire
3 = 2-Wire Level Sensitive
4 = 2-Wire High Speed
5 = RS485 (DSI) Port
9 = Jog

Speed Command

Digit 1

0 = Drive Potentiometer
1 =

A409

[Internal Freq]

2 = 0-10V Input/Remote Potentiometer
3 = 4-20mA Input
4 =

A410

-

A413

[Preset Freq x]

(

t201

-

t202

[Digital Inx Sel] must be set to 4)

5 = RS485 (DSI) Port
9 = Jog Freq

Reserved

Digit 2

Reserved

Digit 3

d013 [Contrl In Status]

Related Parameter(s):

d002

,

P104

,

P105

Status of the control terminal block control inputs.
Important: Actual control commands may come from a source other than the control terminal block.

Values

Default

Read Only

Min/Max:

0/1

Display:

1

1 = Input Present, 0 = Input Not Present

Start / Run FWD Input (I/O Terminal 02)

Bit 0

Direction / Run REV Input (I/O Terminal 03)

Bit 1

Stop Input

(1)

(I/O Terminal 01)

Bit 2

(1)

The stop input must be present in order to start the drive.

When this bit is a 1 the drive can be started.

When this bit is a 0 the drive will stop.

Dynamic Brake Transistor ON (Frame C only) / Reserved (Other Frames)

Bit 3