Specifications, A-2 supplemental drive information – Rockwell Automation 22F PowerFlex 4M User Manual FRN 1.xx - 2.xx User Manual

Page 82

Advertising
background image

A-2

Supplemental Drive Information

PowerFlex 4M Adjustable Frequency Drive FRN 1.xx - 2.xx User Manual
Publication 22F-UM001D-EN-E

Specifications

Drive Ratings

Catalog
Number

Output Ratings

Input Ratings

Branch Circuit Protection

kW (HP)

Amps

Voltage
Range

kVA

Amps Fuses

140M Motor
Protectors

(2)

(3)

Contactors

Min. Enclosure
Volume

(4)

(in.

3

)

100 - 120V AC (±10%) – 1-Phase Input, 0 - 230V 3-Phase Output
22F-V1P6N103

0.2 (0.25) 1.6

90-126

0.8

6.4

10

140M-C2E-C10

100-C09

1655

22F-V2P5N103

0.4 (0.5)

2.5

90-126

1.1

9.0

15

140M-C2E-C16

100-C12

1655

22F-V4P5N103

0.75 (1.0) 4.5

90-126

2.2

18.0

30

140M-D8E-C20

100-C23

1655

22F-V6P0N103

1.1 (1.5)

6.0

90-126

2.9

24.0

40

140M-F8E-C32

100-C30

1655

200 - 240V AC (±10%) – 1-Phase Input, 0 - 230V 3-Phase Output
22F-A1P6N103

0.2 (0.25) 1.6

180-265 0.7

5.3

10

140M-C2E-B63

100-C09

1655

22F-A2P5N103

0.4 (0.5)

2.5

180-265 1.6

6.5

10

140M-C2E-C10

100-C09

1655

22F-A4P2N103

0.75 (1.0) 4.2

180-265 2.0

8.2

15

140M-C2E-C16

100-C12

1655

22F-A8P0N103

1.5 (2.0)

8.0

180-265 5.4

22.3

35

140M-D8E-C25

100-C23

1655

22F-A011N103

2.2 (3.0)

11.0

180-265 5.9

24.3

40

140M-F8E-C32

100-C30

1655

200 - 240V AC (±10%) – 1-Phase Input, 0 - 230V 3-Phase Output, with Filter
22F-A1P6N113

0.2 (0.25) 1.6

180-265 1.3

5.3

10

140M-C2E-B63

100-C09

1655

22F-A2P5N113

0.4 (0.5)

2.5

180-265 1.6

6.5

10

140M-C2E-C10

100-C09

1655

22F-A4P2N113

0.75 (1.0) 4.2

180-265 2.0

8.2

15

140M-C2E-C16

100-C12

1655

22F-A8P0N113

1.5 (2.0)

8.0

180-265 5.4

22.3

35

140M-D8E-C25

100-C23

1655

22F-A011N113

2.2 (3.0)

11.0

180-265 5.9

24.3

40

140M-F8E-C32

100-C30

1655

200 - 240V AC (±10%) – 3-Phase Input, 0 - 230V 3-Phase Output
22F-B1P6N103

0.2 (0.25) 1.6

180-265 0.8

1.9

3

140M-C2E-B25

100-C09

1655

22F-B2P5N103

0.4 (0.5)

2.5

180-265 1.2

2.7

6

140M-C2E-B40

100-C09

1655

22F-B4P2N103

0.75 (1.0) 4.2

180-265 2.1

4.9

10

140M-C2E-B63

100-C09

1655

22F-B8P0N103

1.5 (2.0)

8.0

180-265 4.0

9.5

15

140M-C2E-C16

100-C12

1655

22F-B012N103

2.2 (3.0)

12.0

180-265 6.3

15.0

25

140M-C2E-C20

100-C23

1655

22F-B017N103

3.7 (5.0)

17.5

180-265 8.8

21.1

35

140M-F8E-C25

100-C23

1655

22F-B025N104

(1)

5.5 (7.5)

25.0

180-265 11.4

27.2

45

140M-F8E-C32

100-C37

3441

22F-B033N104

(1)

7.5 (10.0) 33.0

180-265 16.1

38.5

60

140M-F8E-C45

100-C60

3441

380 - 480V AC (±10%) – 3-Phase Input, 0 - 460V 3-Phase Output
22F-D1P5N103

0.4 (0.5)

1.5

340-528 1.5

1.8

3

140M-C2E-B25

100-C09

1655

22F-D2P5N103

0.75 (1.0) 2.5

340-528 3.0

3.5

6

140M-C2E-B40

100-C09

1655

22F-D4P2N103

1.5 (2.0)

4.2

340-528 5.0

6.0

10

140M-C2E-C10

100-C09

1655

22F-D6P0N103

2.2 (3.0)

6.0

340-528 5.2

6.2

10

140M-C2E-C10

100-C09

1655

22F-D8P7N103

3.7 (5.0)

8.7

340-528 7.0

8.3

15

140M-C2E-C16

100-C12

1655

22F-D013N104

(1)

5.5 (7.5)

13.0

340-528 12.9

15.4

25

140M-D8E-C20

100-C23

3441

22F-D018N104

(1)

7.5 (10.0) 18.0

340-528 16.3

19.5

30

140M-F8E-C25

100-C23

3441

22F-D024N104

(1)

11.0 (15.0) 24.0

340-528 21.7

26.1

40

140M-F8E-C32

100-C30

3441

380 - 480V AC (±10%) – 3-Phase Input, 0 - 460V 3-Phase Output, with Filter
22F-D1P5N113

0.4 (0.5)

1.5

340-528 1.5

1.8

3

140M-C2E-B25

100-C09

1655

22F-D2P5N113

0.75 (1.0) 2.5

340-528 3.0

3.5

6

140M-C2E-B40

100-C09

1655

22F-D4P2N113

1.5 (2.0)

4.2

340-528 5.0

6.0

10

140M-C2E-C10

100-C09

1655

22F-D6P0N113

2.2 (3.0)

6.0

340-528 5.2

6.2

10

140M-C2E-C10

100-C09

1655

22F-D8P7N113

3.7 (5.0)

8.7

340-528 7.0

8.3

15

140M-C2E-C16

100-C12

1655

22F-D013N114

(1)

5.5 (7.5)

13.0

340-528 12.9

15.4

25

140M-D8E-C20

100-C23

3441

22F-D018N114

(1)

7.5 (10.0) 18.0

340-528 16.3

19.5

30

140M-F8E-C25

100-C23

3441

22F-D024N114

(1)

11.0 (15.0) 24.0

340-528 21.7

26.1

40

140M-F8E-C32

100-C30

3441

(1)

Catalog suffix ending with ‘4’, such as N104 and N114, indicate that an internal brake IGBT is supplied.

(2)

The AIC ratings of the Bulletin 140M Motor Protector Circuit Breakers may vary. See

Bulletin 140M Motor Protection

Circuit Breakers Application Ratings

.

(3)

Manual Self-Protected (Type E) Combination Motor Controller, UL listed for 208 Wye or Delta, 240 Wye or Delta, 480Y/
277 or 600Y/347. Not UL listed for use on 480V or 600V Delta/Delta, corner ground, or high-resistance ground systems.

Advertising