Chapter 4 Manage the Switch via the Device Manager Web Interface

Enable Static and Connected
Routing

Before you can enable static and connected routing, you must reallocate switch
memory for routing, as described on

page 136

.

To enable routing, from the Configure menu, choose Routing.

From the Routing window, you can enable connected routing only or both static
and connected routing. When static routing is enabled, connected routing is
enabled by default. For more information about these routing types, refer to

Static and Connected Routing on page 84

.

Enable Connected Routing Only

To enable connected routing only, check Enable Routing and click Submit.

No further configuration is required for connected routing.

Enable Both Static and Connected Routing

To enable both static and connected routing, follow these steps.

1. Check Enable Routing and click Submit.

2. Configure static route information as described below.

Field

Description

Destination Network

The IP address of the destination.

Destination Mask

The subnet mask of the destination.

Next Hop Router

The IP address of the router where this device will send the packets for the
specified destination.