Troubleshoot the Switch

This chapter helps you resolve issues related to Stratix 8000 and Stratix 8300
switches and perform common functions, such as resetting a switch.

For additional troubleshooting, refer to the following:

Diagnose Cabling Problems on page 131

View System Log Messages on page 132

IP Address Issues

Following are some basic troubleshooting tips for issues related to the switch IP
address.

Topic

Page

IP Address Issues

169

Device Manager Web Interface Issues

170

Switch Performance

170

Access Direct Managed Mode

171

Restart or Reset the Switch

172

Recover the Switch Firmware and Restore Factory Defaults

173

Troubleshoot a Firmware Upgrade

174

Table 21 - IP Address Issues

Issue

Resolution

IP address is not received from DHCP server

If the switch does not receive an IP address from an upstream device operating as a DHCP server, make sure that the
upstream device is operating as a DHCP server and again follow the procedures to set up the switch in

Chapter 2, Getting

Started

.

Switch has wrong IP address

If the switch is installed in your network but you cannot access the switch because it has the wrong IP address, assign a
new switch IP address.

Refer to Access Direct Managed Mode on page 171

to assign the IP address, and then update the

switch IP address on the Device Manager Express Setup window.