Chapter 1 Install the Switch
• Temperature surrounding the unit does not exceed 60 °C (140 °F).
• Cabling is away from sources of electrical noise, such as radios, power lines,
and fluorescent lighting fixtures.
• Switch is grounded to a bare metal surface, such as a ground bus or a
grounded DIN rail.
Parts List
Verify that you have these items.
If you plan to install a PoE expansion module, verify that you have a PoE power
connector, as shown below.
IMPORTANT
When the switch is installed in an industrial enclosure, the
temperature within the enclosure is greater than normal room
temperature outside the enclosure.
The temperature inside the enclosure cannot exceed 60 °C (140 °F), the
maximum ambient enclosure temperature of the switch.
1
1783-MS10T switch
(1)
(1) The 1783-MS10T switch is shown as only an example.
2
Documentation
3
Power and alarm relay connectors (qty. 2)
4
Console cable
5