Rockwell Automation 1783-Mxxx Stratix 8000 and 8300 Ethernet Managed Switches User Manual User Manual

Page 191

Advertising
background image

Rockwell Automation Publication 1783-UM003I-EN-P - March 2014

191

Cables and Connectors Appendix D

Figure 19 - Four Twisted-pair Straight-through Cable Schematic

When connecting the ports to 10BASE-T- and 100BASE-TX-compatible
devices, such as switches or repeaters, you can use a two or four twisted-pair,
crossover cable.

The following figures show these schematics:

Two twisted-pair, crossover cable schematics
Four twisted-pair, crossover cable schematics

Use a straight-through cable to connect two ports only when one port is
designated with an X. Use a crossover cable to connect two ports when both
ports are designated with an X or when both ports do not have an X.

You can use Category 3, 4, or 5 cabling when connecting to 10BASE-T-
compatible devices. You must use Category 5 cabling when connecting to
100BASE-TX-compatible devices

.

Figure 20 - Two Twisted-pair Crossover Cable Schematic

IMPORTANT

Use a four twisted-pair, Category 5 cable when connecting to a 1000BASE-T-
compatible device or PoE port.

1 TPO+
2 TPO-
3 TP1+
6 TP1-

1 TP1+

Switch

Router or Personal Computer

2 TP1-
3 TPO+
6 TPO-

4 TP2+
5 TP2-
7 TP3+
8 TP3-

4 TP3+
5 TP3-
7 TP2+
8 TP2-

Switch

3 TD+
6 TD–

1 RD+

2 RD–

Switch

3 TD+

6 TD–

1 RD+

2 RD–