Chapter 1 Install the Switch
4. Insert the exposed part of the positive wire into the DC + connection and
the exposed part of the return wire into the DC - connection.
5. Make sure that you cannot see any wire lead; only wire with insulation can
extend from the connector.
6. Use a ratcheting-torque screwdriver to torque the power connector captive
screws above the installed wire leads to 0.23 N•m (2.0 lb•in).
7. Connect the other end of the positive wire (the one connected to DC +)
to the positive terminal on the DC power source, and connect the other
end of the return wire (the one connected to DC -) to the return terminal
on the DC power source.