Dual-purpose port status indicators – Rockwell Automation 1783-Mxxx Stratix 8000 and 8300 Ethernet Managed Switches User Manual User Manual

Page 177

Advertising
background image

Rockwell Automation Publication 1783-UM003I-EN-P - March 2014

177

Status Indicators Appendix A

Dual-purpose Port
Status Indicators

The status indicators on a dual-purpose port, as shown in the following figure,
show whether the RJ45 connector or an SFP module is active. The port can be
configured as either a 10/100/1000 port through the RJ45 connector or as an
SFP module, but not both. The status indicators show which port is being used
and the current port activity.

Table 25 - Dual-purpose Port Status Indicators

Status

Description

Off

No link.

Solid green

A link is present.

Flashing green

The port is sending or receiving data.

Flashing amber

A link blocked by STP is sending or receiving data.

Alternating green
and amber

A link is faulted. Error frames can affect connectivity. Excessive collisions, CRC errors, and
alignment and jabber errors are monitored for a link-fault indication (RJ45 connection only).

Solid amber

The port is not forwarding. The port was disabled by management, or there is an address or STP

violation.
After a port is reconfigured, the port status indicator can remain amber for as many as
30 seconds while STP checks the network for possible loops.