Rockwell Automation Publication 1783-UM003I-EN-P - March 2014

55

Getting Started Chapter 2

Command Line Interface

You can manage the switch from the command-line interface (CLI) by
connecting your personal computer directly to the switch console port or
through the network by using Telnet.

Follow these steps to access the CLI through the console port.

1. Connect the supplied RJ45-to-DB-9 adapter cable to the standard 9-pin

serial port on the personal computer.

2. Connect the other end of the cable to the console port on the switch.

3. Start a terminal-emulation program on the personal computer.

4. Configure the personal computer terminal emulation software for

9600 bps, 8 data bits, no parity, 1 stop bit, and no flow control.

WARNING: The console port is intended for temporary local
programming purposes only and not intended for permanent
connection. If you connect or disconnect the console cable with power
applied to this module or the programming device on the other end of
the cable, an electrical arc can occur. This could cause an explosion in
hazardous location installations. Be sure that power is removed or the
area is nonhazardous before proceeding.