Install the Switch Chapter 1

Wire the DC Power Source
for the PoE Expansion
Module (optional)

Power supply requirements for a PoE expansion module depend on your
application.

Follow these steps to wire DC power to the PoE expansion module.

1. Locate the power connector and identify the positive and return DC

power connections.

2. Measure a length of 0.82…0.52 mm

2

(18…20 AWG) copper wire long

enough to connect to the DC power source.

3. Use an 18-gauge wire-stripping tool to strip each of the two wires to

6.3 mm (0.25 in.) ± 0.5 mm (0.02 in.).

Do not strip more than 6.8 mm (0.27 in.) of insulation from the wire.
Stripping more than the recommended amount of wire can leave exposed
wire from the connector after installation.

WARNING: Before performing any of the following procedures, make sure that
power is removed from the DC circuit or the area is nonhazardous before
proceeding.

WARNING: To comply with the CE Low Voltage Directive (LVD), this equipment
must be powered from a source compliant with the safety extra low voltage
(SELV) or protected extra low voltage (PELV).

To comply with UL restrictions, this equipment must be powered from a source

compliant with Class 2 or Limited Voltage/Current.

Application

Power Consumption

Power Supply per Port

Allen-Bradley Products

PoE only
IEEE 802.3af

44…57V DC (48V DC nom) 15.4 W, max

Switched mode power supplies:
1606-XL Standard
1606-XLE Essential
1606-XLP Compact
1606-XLS Performance

PoE and PoE +
IEEE 802.3at Type 2

50…57V DC (54V DC nom) 15.4 W, max for PoE

30 W, max for PoE+

32437-M

DC +

DC -

31784-M

6.8 mm (0.27 in.)