Prepare to Use the ControlNet Scanner 2-3

Understand ControlNet
Data transfer

The ControlNet system is designed to do this:

• Provide high-speed, repeatable, deterministic I/O transmission.
• Let control and message information co-exist on the same

physical media.

• Make sure that I/O data transfers are not affected by:

• programming-terminal activity.
• inter-scanner message activity on the network.

Scheduled Data Transfer Operations on a ControlNet Network

ControlNet scheduled data transfer on a 1747-SCNR Scanner:

• is continuous.
• transmits on the network asynchronously to the ladder logic

program scan.

• occurs at the actual rate that is determined by RSNetWorx for

ControlNet software.

For discrete I/O data transfer between logic scans (during
housekeeping), the following updates occur.

• The gathered input image is moved from the scanner to the SLC

processor's input image file for use during the next logic scan.

• The 1747-SCNR output data is updated with data from the SLC

processor output image file and is sent during the next
scheduled communication.

M0 and M1 files are data files that reside in the 1747-SCNR scanner
only. Data from these files will be available to the SLC processor using
ladder instructions. Scheduled data update will be triggered by the
Housekeeping period start, which occurs once per scan. This process
is illustrated below.

Data
Table
Files

Lo

gi

c S

ca

n

Scheduled
Data
Private
Memory
Buffers

Sc

he

dule

d Da

ta

Tr

an

sf

er

s

Housekeeping

41554

SLC 500 Program Scan Data Tables Files Housekeeping

Data Update

1747-SCNR Scheduled Data