Publication 1763-UM001D-EN-P - March 2011

114 Using the LCD

Follow these steps to view and change the data values of the bit file B3.

1. On the Main Menu screen, select Monitoring by using the Up and

Down keys on the LCD keypad.

2. Then, press the OK key on the LCD keypad. The Bit/Integer File Select

screen is displayed, as shown below.

3. If Bit is selected, as shown in

step 2

, press the OK key.

If not selected, press the Up or Down key to select it and then press the
OK key.

4. The current data value (ON) of the B3:0/0 bit is displayed, as shown

below. Note that “0/0” is flashing, which means the cursor is at the
target bit position.