64 Wiring Your Controller

1762-IF2OF2 Input Type Selection

Select the input type, current or voltage, using the switches located on the
module’s circuit board and the input type/range selection bits in the
Configuration Data File. Refer to MicroLogix 1100 Programmable Controllers
Instruction Set Reference Manual, publication 1763-RM001. You can access
the switches through the ventilation slots on the top of the module. Switch 1
controls channel 0; switch 2 controls channel 1. The factory default setting for
both switch 1 and switch 2 is Current. Switch positions are shown below.

1762-IF2OF2 Output Type Selection

The output type selection, current or voltage, is made by wiring to the
appropriate terminals, Iout or Vout, and by the type/range selection bits in the
Configuration Data File. Refer to MicroLogix 1100 Programmable Controllers
Instruction Set Reference Manual, publication 1763-RM001.

ATTENTION

Analog outputs may fluctuate for less than a second
when power is applied or removed. This
characteristic is common to most analog outputs.
While the majority of loads will not recognize this
short signal, it is recommended that preventive
measures be taken to ensure that connected
equipment is not affected.

1

ON

2

Ch0 Ch1

Current (ON) Default

Voltage (OFF)