Publication 1763-UM001D-EN-P - March 2011

90 Communication Connections

Cable Selection Guide

1761-CBL-PM02

(2)

1761-CBL-AP00

(2)

Cable

Length

Connections from

to AIC+

External
Power Supply
Required

(1)

Power
Selection
Switch
Setting

(1)

1761-CBL-AP00

(2)

1761-CBL-PM02

(2)

45 cm (17.7 in.)

2 m (6.5 ft)

SLC 5/03 or SLC 5/04 processors, ch 0 port 2

yes

external

MicroLogix™ 1000, 1200, or 1500 ch 0

port 1

yes

external

MicroLogix™ 1100 ch 0

port 1

yes

external

PanelView 550 through NULL modem
adapter

port 2

yes

external

DTAM Plus / DTAM Micro

port 2

yes

external

PC COM port

port 2

yes

external

(1)

External power supply required unless the AIC+ is powered by the device connected to port 2, then the selection switch should be set to cable.

(2)

Series C or later cables are required.

1761-CBL-HM02

(2)

1761-CBL-AM00

(2)

Cable

Length

Connections from

to AIC+ External

Power Supply
Required

(1)

Power
Selection
Switch Setting

1761-CBL-AM00

(2)

1761-CBL-HM02

(2)

45 cm (17.7 in.)
2 m (6.5 ft)

MicroLogix™ 1000, 1200, or 1500 ch 0

port 2

no

cable

MicroLogix™ 1100 ch 0

port 2

Yes

external

to port 2 on another AIC+

port 2

yes

external

(1)

External power supply required unless the AIC+ is powered by the device connected to port 2, then the selection switch should be set to cable.

(2)

Series C or later cables are required.