4. Close the Connection Manager.
4. Under System Management Tools, select Security >
Mappings & Trusts.
5. Verify that PIBuffSubSystemService is listed in the Trusts
tab.
6. Exit the System Management Tools.
7. Go to
Start > All Programs > Rockwell Software > FactoryTalk
Historian SE > Interface Configuration Utility. The Interface
Configuration Utility dialog box appears.
8. From the Interface list, select the name of the FactoryTalk
Historian Live Data Interface.
9. From the menu bar, select Tools > Buffering. The Buffering
dialog box appears.
10. In the Choose Buffer Type pane, select the Enable buffering
with PI Buffer Subsystem option.
11. Click Yes in the confirmation message box that appears. Wait
until the status box at the bottom of the Buffering dialog box
displays
Current Configuration: Good.
NOTE
If you delete an interface and recreate the interface (with the same
ID) on another computer, you will get errors unless you restart the
computer on which the deleted interface was located. Restarting