NOTE

Perform the steps described below on each computer with the Asset
Framework service installed.

To configure the AF service to communicate with the PIFD SQL
database:

1. In Windows Explorer, navigate to the following folder in the

Program Files directory:

Rockwell Software\FactoryTalk

Historian\PIPC\AF\.

2. Open the AFService.exe.config file in a text editor.
3. Navigate to the <appSettings> section, and in the add element

with the key=connectString attribute update the values of
the server attribute:
server=SQLServer\SQLInstance
For example:

• If the SQL Server is running on a computer cluster, type the

IP address of the clustered resource as the SQLServer value.

• If the SQL Server is configured to use the SQL Server

database mirroring, add the failover partner attribute after
the server attribute with the following values:
failover partner=SQLServer\SQLInstance