Troubleshooting FactoryTalk Historian Chapter 7


Rockwell Automation Publication HSE-IN024A-EN-E–December 2012

109

The Windows Administrators group should appear in the
Members list. If it does not, do the following:

1. Click Add. The Select User or Group dialog box appears.
2. Select Windows Administrators and click OK. The group

is added to the FTHAdministrators group.

3. Click OK to close the dialog box.

Use this section to find information about the following types of
error and warning messages:

• General (page 109)
• No Connection to FactoryTalk Directory (page 111)

Use this section to find information about the following error
messages:

• Error: System is a PINs Node (page 109)
• Error: Server Not Found (page 110)
• Error: Failure to Retrieve Interface Information (page 111)

Message

FactoryTalk Historian SE server setup has determined that this is a
PINS node. The FactoryTalk server installation cannot continue.

Please completely remove the Historian SDK and rerun setup.

Cause

The error occurs if you install a FactoryTalk Historian SE server on a
computer that already has FactoryTalk Historian SE Clients
(ProcessBook, DataLink) or components (System Management

Tools) installed.

Resolution

Remove the Historian Software Development Kit (Historian SDK)
using Control Panel > Programs > Programs and Features.

Resolving Error and
Warning Messages

General

Error: System is a PINs Node