Appendix A Configuring Historian Servers in High Availability Mode


122

Rockwell Automation Publication HSE-IN024A-EN-E–December 2012

Click Next.

16. On the Verify Selections page, verify the collective data, and

click Next.
The Conversion Progress page displays the status and
individual steps of the conversion process. Wait until the
conversion is complete.

17. If the Server ID Mismatch dialog box appears, select Accept

the new ID, and click OK.

18. On the Finished page, click Finish. The new collective is

displayed in the Collective Manager dialog box.

TIP

For more information on collectives, refer to the Collective
Manager Help. To access it, select Help > Contents from the
menu bar of the Collective Manager dialog box.

Use the Collective Manager to verify that the members of your
server collective are communicating.

To check communication of the members of a server collective:

1. Click

Start > All Programs > Rockwell Software > FactoryTalk

Historian SE > FactoryTalk Historian SE System > Collective
Manager
. The Collective Manager dialog box appears.
If the server collective does not appear under Collectives, you

must enable communication between the Collective Manager
and the collective:

1. Select File > Connections. The Connection Manager

dialog box appears.

2. Click the check box next to the name of the server collective

to select it.

Verifying Communication
Between Server Collective
Members