Post-Installation Tasks Chapter 5


Rockwell Automation Publication HSE-IN024A-EN-E–December 2012

59

• If you want to enable the encrypted communication

between the AF service and the AF SQL database, add the
encrypt=Yes attribute to the code, for example:

• If you want to configure other options, refer to the

Microsoft SQL Native Client documentation.

4. Save the file.
5. If the Asset Framework service is running, restart it for the

changes to take effect:

1. Go to

Start > All Programs > Administrative Tools >

Services.

2. In the Services dialog box, right-click PI AF Server 2.x and

select Restart.

Once you have the FactoryTalk Historian Asset Framework and the
FactoryTalk Historian SE Server installed, you need to set up
synchronization between the AF service and the Historian server.
This process is called the

MDB to AF transition. For more

information, refer to the

FT Historian SE MDB to AF Transition

Guide.

To verify the MDB to AF synchronization:

1. Click

Start > All Programs > Rockwell Software > FactoryTalk

Historian SE > System Management Tools. The System
Management Tools
dialog box appears.

Perform the MDB to AF
Synchronization

Verify the MDB to AF
Synchronization