Chapter 6 Configuring FactoryTalk Historian


66

Rockwell Automation Publication HSE-IN024A-EN-E–December 2012

Groups

Description and privileges

FTHAdministrators

It represents Historian server administrators and has
read-and-write access to all Historian server resources and default

points, except the following database tables:

• PIDS
• PIHeadingSets
• PIPOINT

You can or cannot do the following with the FTHAdministrators
group:

• You can:

Map it to the AD group that represents your Historian server

system administrators.

Adjust its access permissions to meet your needs.
Fully disable it.

• You cannot:

Delete it.

FTHEngineers

A preconfigured group with the following privileges:

• Create, modify, and delete point definitions.
• Read and write access to the following database tables:

PIDS
PIHeadingSets
PIPOINT

FTHOperators

A preconfigured group with the following privileges:

• Read any point definition.
• Read any point’s historical data set.

FTHSupervisors

A preconfigured group with the following privileges:

• Read any point definition.
• Read any point’s historical data set.

When the users belonging to the FTHSupervisors group create

points in the FactoryTalk Administration Console, they get the
following privileges to these points:

• Add new point data to any point’s historical data set.
• Add, modify, and delete point data.