Distributing licenses without fhse3add activation – Rockwell Automation FactoryTalk Historian SE 3.01 Installation and Configuration Guide User Manual

Page 83

Advertising
background image

Configuring FactoryTalk Historian Chapter 6


Rockwell Automation Publication HSE-IN024A-EN-E–December 2012

83

<BaseLicenseCount> = 2400

2. Calculate the number of licenses for the Rockwell license pool.

<RockwellLicensePool> = ∑ <FHLD licenses> + ∑ <FHSE
licenses> - <BaseLicenseCount>

<RockwellLicensePool> = 5000 + 12000 - 2400
<RockwellLicensePool> = 14600

3. Calculate the number of licenses for the General license pool.

<GeneralLicensePool> = ∑ <PTY3 licenses> +
<BaseLicenseCount> + ∑ <FHSE3ADD licenses>

<GeneralLicensePool> = 500 + 2400 + 2000
<GeneralLicensePool> = 4900

In this example, the total of 19500 licenses has been distributed in
the following way:

Licenses and license pools

Values

License total

19500

Rockwell license pool

14600

General license pool

4900

In the following example we will calculate how licenses will be
distributed between the General and Rockwell license pools without
FHSE3ADD license activations.

We will use the following values:

Activation

Value

FHSE.2K

2000

12000

FHSE.10K

10000

FHSE3ADD.2K

0

0

Distributing Licenses
without FHSE3ADD
Activation

Advertising