Metrohm 732 IC Detector User Manual

Page 181

Advertising
background image

6 Interfaces

732 IC Detector / 733 IC Separation Center

174

Object

Meaning

Entry range/Selection

³

Ã

.

M

ark

Trigger marking signal (=<MARK> key)

1

7

15

³

Ã

.

Zeroo

ff

Switch off auto-zero (=<ZERO OFF> key)

1

9

15

³

Ã

.

Pl

ot

Trigger graphics plot (=<PLOT> key)

1

10

15

³

Ã

.

Po

larity

Switch polarity at analog output

1

11

15

³

Ã

.

S

elect

Select (=<SELECT> key)

1

13

15

³

Ã

.

Q

uit

Quit (=<QUIT> key)

1

14

15

³

À

.

E

nter

Enter (=<ENTER> key)

1

15

15

Ã

.

G

raphics

General graphics parameters

³

Ã

.

G

rid

Grid lines on graphics output

on, off

³

Ã

.

F

rame

Frame on graphics output

on, off

³

À

.

R

ecorder

Setting of printout

³

À

.

W

idth

Relative width of printout

0.4

0.8

1.0

À

.

P

eripherals

Peripheral instruments

Ã

.

W

ith733

Operation with 733 IC Separation Center

on

, off

À

.

With70

9

Operation with 709 IC Pump

on

, off

&A

ssembly

Basic elements of the assembly

³

Ã.

M

eas

Measurement

³

À

.

S

tate

On/off switching of measurement

on

, off

³

À.

O

utputs

Remote lines

Ã

.

S

mplX

³

Activate (on) or deactivate (off) remote output lines on, off

Ã

.

A

utoEOD

³

Automatic output of EOD on program end and

"return" with loop programs

on

, off

Ã

.

Se

tLines

³

³

³

³

³

³

³

³

³

³

³

³

Set remote outputs 1

16:

Interface "709 IC Pump": outputs 1

8

Interface "Remote":

outputs 9

16

active

setting of a static signal

inactive

resetting of the static signal

pulse

output a pulse (length ca. 150 ms)

off

do not set line

$G

³

Ã

.

L1

Signal of output line

1

(pin 5)

active, inactive, pulse, off

³

Ã

.

L2

Signal of output line

2

(pin18)

active, inactive, pulse, off

³

Ã

.

L3

Signal of output line

3

(pin 4)

active, inactive, pulse, off

³

Ã

.

L4

Signal of output line

4

(pin17)

active, inactive, pulse, off

³

Ã

.

L5

Signal of output line

5

(pin 3)

active, inactive, pulse, off

³

Ã

.

L6

Signal of output line

6

(pin16)

active, inactive, pulse, off

³

Ã

.

L7

Signal of output line

7

(pin 1)

active, inactive, pulse, off

³

Ã

.

L8

Signal of output line

8

(pin 2)

active, inactive, pulse, off

³

Ã

.

L9

Signal of output line

9

(pin 5)

active, inactive, pulse, off

³

Ã

.

L10

Signal of output line 10

(pin18)

active, inactive, pulse, off

³

Ã

.

L11

Signal of output line 11

(pin 4)

active, inactive, pulse, off

³

Ã

.

L12

Signal of output line 12

(pin17)

active, inactive, pulse, off

³

Ã

.

L13

Signal of output line 13

(pin 3)

active, inactive, pulse, off

³

Ã

.

L14

Signal of output line 14

(pin16)

active, inactive, pulse, off

³

Ã

.

L15

Signal of output line 15

(pin 1)

active, inactive, pulse, off

³

À

.

L16

Signal of output line 16

(pin 2)

active, inactive, pulse, off

À

.

R

esetLines

Set remote outputs 1

16 to ”off”

$G

Advertising