Operator’s manual – Great Plains DICKEY-john MVT Monitor Operator User Manual

Page 118

Advertising
background image

OPERATOR’S MANUAL

IntelliAg MVT

11001-1643-201401

TROUBLESHOOTING & ALARM CODES / 109

229

Hopper Sensors Installed
Incorrectly Alarm

HOPPER SENSORS ARE NOT
INSTALLED SEQUENTIALLY ON A
MODULE.
1. Incorrect hopper sensor connections.
2. Defective hopper sensor.
3. Defective module or damaged module
harness.

1. Verify hopper sensors are connected
sequentially on all modules as instructed in
INSTALLATION.
2. Inspect hopper sensor for damage or
replace.
3. Inspect module and/or module harness
for damage. Replace if necessary.

230

Pressure Sensors
Installed Incorrectly Alarm

PRESSURE SENSORS ARE NOT
INSTALLED SEQUENTIALLY ON A
MODULE.
1. Incorrect pressure sensor connections.
2. Defective pressure sensor.
3. Defective module or damaged module
harness.

1. Verify pressure sensors are connected
sequentially on all modules as instructed in
INSTALLATION.
2. Inspect pressure sensor for damage or
replace.
3. Inspect module and/or module harness
for damage. Replace if necessary.

231

Seeding Detected on a
Tramlined Row Alarm

Occurs if a tramlined row does not shut off
the row unit and seeds continue to be
detected. (Only possible if system supports
tramlining).
1. Output to row mapping is assigned
incorrectly.
2. Seed sensor malfunction.

1. Check output row mapping.
2. Check seed sensor to ensure no false
triggering.
3. Inspect and verify Tramline output is
shutting off seeds correctly.

232

RPM Sensor Low Limit
Exceeded With Control
Channel Shutdown Alarm

RPM HAS DROPPED BELOW THE
DISABLE CONTROL ON LOW ALARM
SETTING ON THE ACCESSORY SETUP
SCREEN.
1. Defective RPM sensor.
2. Damaged module harness.
3. Defective module.
4. Low RPM

1. Inspect RPM sensor for damage.
Replace if necessary.
2. Inspect module harness for damage.
Repair or replace.
3. Inspect module for damage. Replace if
necessary.
4. Increase RPM.

233

Channel Activation Alarm

CHANNEL DELAY OR PRECHARGE IS
ENABLED. DURING THIS THE CONTROL
WILL RUN WITHOUT GROUND SPEED
OR WITHOUT THE IMPLEMENT DOWN.

1. Acknowledge alarm to activate control
channels.
2

.

Acknoweldge alarm and disable Delay or

Precharge to stop control.

235

New Member Module
Detected Alarm

1. New member module has been found.

1. Assign sensors to the new module at the
Module Configuration Setup screen and its
position.

236

Intermittent Member
Module Detected Alarm

1. A member module that had previously
failed communication has come online.

1. Inspect harness connections to this
module.

237

Product Level Low Alarm

1. Calculated product level has dropped
below alarm level.

1. Fill product bin and reset level.

240

Seeding Detected on a
Control Off Row Alarm

1. Channel turned off and seed continues
to be detected.

1. Check seed dispensing unit for proper
shut off.

241

Control Not Active With
Implement Lowered and
Speed

1. Control will not operate while on a setup
screen.

1. Navigate to the Work Screen to activate
the control.
2. Raise implement and stop forward speed
to clear alarm.

246

Master Switch Softkey
Press Alarm

1. Warning of action associated with key
press.

1. Press Control Start key to activate
control.

249

Control Channel
Activation Alarm

1. Controls will run without ground speed or
without implement lowered. Channel
Manual Mode or Precharge is enabled.
During this the control will run without
ground speed or without the implement
down.

1. Acknowledge alarm to activate control
channels.
2. Acknowledge alarm and disable manual
or precharge to stop control.

ALARM
#

ALARM

PROBABLE CAUSE

CORRECTIVE ACTION

Advertising