Operator’s manual – Great Plains DICKEY-john MVT Monitor Operator User Manual

Page 98

Advertising
background image

OPERATOR’S MANUAL

IntelliAg MVT

11001-1643-201401

CUSTOMIZING THE WORK SCREEN / 89

SEED COUNT ACCUM ROW

Seed Count Accum Row scans through all of the active seed rows and
displays the seed count for each row as detected by the seed sensors. The
value to the left side displays the current row number. The value to the right
is the seed count. The scan continues sequentially in four-second intervals
unless a particular row number is selected for continuous view. The seed
count function is enabled/disabled on the Accumulators/Seed Count/
Distance Count screen. This Data Item displays on an entire row of the
Work screen.

DISTANCE ACCUMULATOR

Distance Accumulator displays the distance covered in feet (ft). This
accumulator is independent of any other area accumulator and can be reset
to 0.0 at any time. Current distance is retained after power down.

CHANNELS 1 - 2 MATERIAL ACCUMULATION

Channels 1 - 2 Material Accum displays the current accumulated material
for Channels 1 - 2. Material is accumulated according to the applied rate.
Does not function if channel is planter control.

ACCESSORY INPUT - PRESSURE SCAN

Pressure Scan scans through all active pressure sensors sequentially
displaying the actual pressure measured in oz/in

2

(kPa) in four-second

intervals. The current sensor is identified by the number above the pressure
symbol.

ACCESSORY INPUT - RPM SCAN

RPM Scan scans through all active shaft/fan sensors sequentially
displaying the actual RPM measured in four-second intervals. The current
sensor is identified by the number displayed above the RPM symbol.

Advertising