Operator’s manual, Seed row setup – Great Plains DICKEY-john MVT Monitor Operator User Manual

Page 69

Advertising
background image

OPERATOR’S MANUAL

IntelliAg MVT

11001-1643-201401

60 / SYSTEM CONFIGURATION

SEED ROW SETUP

Seed Row Assignment controls the rows that are monitored and the
distance between rows and implement width.

Individual rows can be set to ON or OFF.

Any detected row can be set to OFF.

Rows set to OFF remain off until they are turned ON again or are set to
ON through Pattern Select.

Rows set to OFF are ignored by the system and will not report seed
data or react to row failures.

To Assign Rows:

1. Press the Seed Rows button.
2. Use the rotary knob to highlight the yellow input box.
3. Press in the rotary knob to select or change the value.

NOTE:

The Next Rows button is only
present if more than 24 rows
are configured.

Figure 53

Seed Row Assignment Screen

ROW WIDTH

Row Width is used for seed rate data and control calculations and is the
distance in inches (centimeters) between rows with a resolution of 0.1. This
value updates automatically with changes in the On/Off Pattern Setting
option if the Auto Update Width option is set to Enabled.

AUTO UPDATE WIDTH

Auto Update Width automatically updates the Row Width and Implement
Width settings when changes are made to the Pattern Setting option.

IMPORTANT: Depending on the configured number of rows, some On/

Off pattern settings can result in erroneous row width or
implement width updates if the Auto Update Width is
enabled. Always check the calculated values for
accuracy when the Auto Update Width is enabled. If the
adjusted values are not correct, disable the Auto Update
Width feature and manually enter a row width and
implement width.