72 / ACCESSORY SENSORS

To Set the Active State and Alarms of Hopper Sensors:

The Hopper Set screen controls the active state of the hopper sensor as
well as the alarm delay time.

1. At the Hopper Assignment screen, press the Hopper Set button.
2. Use the rotary dial to highlight the yellow input box.
3. Push in the rotary dial to select or enter a value.
4. Push in the rotary dial to accept.

Figure 61

Hopper Set Screen

LOGIC LEVEL

Logic Level sets the active state of the sensor and allows flexibility to
connect sensors that have different active outputs. There are two settings
available:

NOTE:

For a Dj Hopper Level sensor,
this value should be set to
ACTIVE LO.

ACTIVE HIGH

Sets the active state to “High” signifying that an alarm is generated if
the sensor’s output is in a high state. Use this setting if the connected
sensor outputs a high condition when active.

ACTIVE LO

Sets the active state to “Low” signifying that an alarm is generated if
the sensor’s output is in a low state. Use this setting if the connected
sensor outputs a low condition when active.

ALARM DELAY

Alarm Delay controls the delay time between the detection of a hopper
alarm condition and the generation of the resulting alarm. The value is
entered in seconds.

CHANNEL

Assigns the hopper sensor to a specific control channel.