Operator’s manual, Hopper sensor setup – Great Plains DICKEY-john MVT Monitor Operator User Manual

Page 80

Advertising
background image

OPERATOR’S MANUAL

IntelliAg MVT

11001-1643-201401

ACCESSORY SENSORS / 71

HOPPER SENSOR SETUP

The number of hopper sensors connected to each module is entered at this
screen. The hopper # value is automatically configured for proper
numbering sequence for each module based upon the module address
value if an auto configuration is performed.

The Hopper Assignment screen displays:

Module address

Type

Number of hoppers

Hopper numbers for the system

TIP: Press Auto Config button to automatically populate installed
sensors.

To Manually Assign Hoppers:

1. At the Hopper Setup screen, press the Hop Assign button.
2. Enter the number of hoppers assigned for each module.
3. Press the Sensor Detect button to detect and test the hopper sensors.

– An hour glass appears in the upper right corner during system

configuration.

4. If the number of sensors detected on each module is not in agreement

with the number of sensors entered, an alarm activates.
– Verify that the number of sensors entered on the Hopper

Assignment screen matches the actual number of sensors
connected.

– Confirm that all hopper sensor harnessing is connected properly.

Figure 60

Hopper Assignment Screen

Advertising