OPERATOR’S MANUAL

IntelliAg MVT

11001-1643-201401

38 / MATERIAL SETUP

MATERIAL CONFIGURATION

After creating a material name that appears at the top of the Material
Configuration screen, material parameters are entered that include:

Type

Units

Preset Method

Seeds per Revolution

Disc Low/High Limits

Alarms

On/Off Pattern

To Define Material Parameters:

1. At the Materials screen, use the rotary button to highlight each yellow

input box.

2. Push in the rotary button to select or change the value.
3. Press the More button for additional parameters.

Figure 36

Planter Control Setup Screen - Preset Method Disabled

TYPE

Type establishes the desired type of application control channel used for a
specific material. This step is very important. Material type must
correctly match Control type.

NOTE:

Refer to the Operate section for
setup and operate instructions.

MONITOR ONLY

Monitor Only is typically used for ground drive applications to monitor
population with high and low alarms. All seeding control channels MUST be
disabled in this configuration and/or no rows assigned to those seeding
channels.

IMPORTANT: In monitor only mode, a material name must be selected at

the Row Monitor Setup screen to activate high and low
population alarms.

Type

Used for

Planter Control

seeding on a row crop planter

Monitor Only

population monitoring only